Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 3/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | LPV-20-5 | LPV-20-12 | LPV-20-15 | LPV-20-24 | |
Output | DC Voltage | 5V | 12V | 15V | 24V |
Rated Current | 4A | 1.7A | 1.3A | 0.83A | |
Current Range | 0~4A | 0~1.7A | 0~1.3A | 0~0.83A | |
Rated Power | 20W | 20W | 19.5W | 19W | |
Ripple & Noise (max.) Note.2 | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | |
Voltage Tolerance Note.3 | ±5.0% | ±5.0% | ±5.0% | ±5.0% | |
Line Regulation | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Load Regulation | ±2.0% | ±2.0% | ±2.0% | ±2.0% | |
Setup,Rise time Note. 6 | 500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load | ||||
Hold time (Typ.) | 50ms/230VAC 16ms/115VAC at full load | ||||
Input | Voltage Range Note.4 | 90 ~ 264VAC 127 ~ 370VDC | |||
Frequency Range | 47~63HZ | ||||
Efficiency(Typ.) | 77% | 81% | 83% | 83% | |
AC Current(Typ.) | 0.55A/115VAC 0.35A/230VAC | ||||
Inrush Current (max.) | COLD START 70A(twidth=215£g s measured at 50% Ipeak) at 230VAC | ||||
Leakage Current | 0.25mA / 240VAC | ||||
Protection | Over Load | 110 ~ 150% rated output power | |||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||
Over Voltage | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 17.5 ~ 21V | 28 ~ 32V | |
Protection type : Shut off o/p voltage, clamping by zener diode | |||||
Environment | Working Temperature | -30 ~ +70°c (Refer to "Derating Curve" ) | |||
Working Humidity | 20~90% RH Non-condensing | ||||
Storage temp.& Humidity | -40~+80°C, 10~95%RH | ||||
Temp. coefficient | ±0.03%/°C (0~50°C) | ||||
Vibration | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||
Safety & EMC | Safety Standards | UL879, UL1310, CSA C22.2 No. 207-M89, CAN/CSA C22.2 No. 223-M91, IP67 approved ; design refer to TUV EN60950-1 | |||
(Note 4.) | Withstand Voltage | I/P-O/P:3KVAC | |||
Isolation Resistance | I/P-O/P:>100M Ohms / 500VDC / 25°c/ 70% RH | ||||
EMC Emission | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3 | ||||
EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A | ||||
Others | MTBF | 786.5Khrs min. MIL-HDBK-217F (25°c) | |||
Dimension | 160*30*20mm (L*W*H) | ||||
Packing | 0.20Kg; 60pcs/14.2Kg/0.62CUFT | ||||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°c of ambient temperature. | ||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | |||||
3. Tolerance : includes set up tolerance, line regulation and load regulation. | |||||
4. Derating may be needed under low input voltage. Please check the static characteristics for more details. | |||||
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the | |||||
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. | |||||
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. | |||||
7. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute. |