MODEL | D-50A | D-50B | |||
OUTPUT | OUTPUT NUMBER | CH1 | CH2 | CH1 | CH2 |
DC VOLTAGE | 5V | 12V | 5V | 24V | |
RATED CURRENT | 6A | 2A | 4A | 1.4A | |
CURRENT RANGE Note.6 | 1 -6A | 0.3 - 3A | 1 -6A | 0.2 - 2A | |
RATED POWER | 54W | 53.6W | |||
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 80mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | CH1:4.75-5.5V | CH1:4.75-5.5V | |||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±6.0% | ±2.0% | ±6.0% | |
LINE REGULATION Note.4 | ±0.5% | ±1.0% | ±0.5% | ±1.0% | |
LOAD REGULATION Note.5 | ±1.5% | ±3.0% | ±1.5% | ±3.0% | |
SETUP, RISE TIME | 500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load | ||||
HOLD UP TIME (Typ.) | 50ms/230VAC 10ms/115VAC atfull load | ||||
INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120-370VDC | |||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
EFFICIENCY(Typ.) | 79% | 82% | |||
AC CURRENT (Typ.) | 1.1A/115VAC 0.65A/230VAC | ||||
INRUSH CURRENT (Typ.) | COLD START45A | ||||
LEAKAGE CURRENT | <2mA/240VAC | ||||
PROTECTION | OVERLOAD | 110 ~ 150% rated output power | |||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||||
OVERVOLTAGE | CH1:5.75-6.75V | ||||
Protection type: Shut down o/p voltage, re-power on to recover | |||||
ENVIRONMENT | WORKING TEMP. | -20 - +60°C (Refer to "Derating Curve") | |||
WORKING HUMIDITY | 20 - 90% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -40 -+85°C, 10-95% RH | ||||
TEMP. COEFFICIENT | ±0.03%/°C{0~45°C) | ||||
VIBRATION | 10 - 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes | ||||
SAFETY & | SAFETY STANDARDS | UL60950-1, CB(IEC60950-1) approved | |||
EMC | WITHSTAND VOLTAGE | l/P-0/P:3KVAC l/P-FG:2KVAC 0/P-FG:0.5KVAC | |||
(Note 7) | ISOLATION RESISTANCE | l/P-O/P, l/P-FG, 0/P-FG:100M Ohms/500VDC/25°C/70% RH | |||
EMC EMISSION | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 | ||||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-1, light industry level, criteria A | ||||
OTHERS | MTBF | 413.3K hrs min. MIL-HDBK-217F (25°C) | |||
DIMENSION | 159*97*38mm (L*W*H) | ||||
PACKING | 0.53Kg; 30pcs/20Kg/0.72CUFT | ||||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. | |||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor. | |||||
3. Tolerance : includes set up tolerance, line regulation and load regulation. | |||||
4. Line regulation is measured from low line to high line at rated load. | |||||
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load. | |||||
6. Each output can work within current range. But total output power can't exceed rated output power. | |||||
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies. | |||||
NOTE |