Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 1 Year |
Still deciding? Get samples of US$ 1/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1200W Switching power supply | |||||||
DC output voltage | 12V | 24V | 36V | 48V | 60V | 80V | 110V |
Output voltage tolerance | ±0.1% | ±0.1% | ±0.1% | ±0.1% | ±0.1% | ±0.1% | ±0.1% |
Rated output current | 100A | 50A | 33A | 25A | 20A | 15A | 11A |
Output current range | 0-100A | 0-50A | 0-33A | 0-25A | 0-20A | 0-15A | 0-11A |
Output current range | 200 mVp-p |
200 mVp-p | 200 mVp-p | 200 mVp-p | 200 mVp-p | 200 mVp-p | 200 mVp-p |
Incoming line stability | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stability | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
DC output power | 1200W | 1200W | 1200W | 1200W | 1200W | 1200W | 1200W |
Efficiency | 85% | 85% | 85% | 85% | 85% | 85% | 85% |
DC voltage adjustable range | ±10% | ±10% | ±10% | ±10% | ±10% | ±10% | ±10% |
Input voltage range | 190-240VAC/47~63HZ | ||||||
Input current | 7A/230V | ||||||
Impulse current | 50A/230V | ||||||
Leakage current | <3.5MA/240VAC | ||||||
Overload protection | 105%~150%, type: cut off the output, reset: automatic recovery | ||||||
Overvoltage protection | 115%-135% | ||||||
High temperature protection | ≥70ºC cut off output (0-50ºC) | ||||||
Temperature coefficient | ±0.03%/ºC(0-50ºC) | ||||||
Start, rise, hold time | 1.5S,50MS,20MS | ||||||
Vibration resistance | 10~500HZ, 2G 10min,/1 cycle, duration 60 minutes, each axis | ||||||
Pressure resistance | Between input and output: 1.5KVAC Input and shell: 1.5KVAC Output and shell: 0.5KVAC | ||||||
Isolation resistance | between input and output; input and shell, output and shell; 500VDC/100MΩ | ||||||
Working temperature and humidity | -10ºC~+60ºC (refer to output characteristic diagram), 20%~90%RH | ||||||
Storage temperature and humidity | -20ºC~+85ºC,10%~95%RH | ||||||
Dimensions | 291*132*68mm | ||||||
Weight | 2.35KG | ||||||
Safety standards | Meet UL1950 requirements (not apply for marking) | ||||||