Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 2 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL | MS-25-5 | MS-25-12 | MS-25-24 | |
OUTPUT | DC VOLTAGE | 5V | 12V | 24V |
RATED CURRENT | 5A | 2A | 1A | |
CURRENT RANGE | 0-5A | 0-2A | 0-1A | |
RATED POWER | 25W | 25W | 25W | |
RIPPLE & NOISE (max.) Note.2 | 50mVp-p | 100mVp-p | 100mVp-p | |
VOLTAGE ADJ. RANGE | 4.75 ~ 5.5V | 10.8 ~ 13.2V | 21.6 ~ 26.4V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | 1.00% | |
LINE REGULATION | ±0.5% | ± 0.5% | ± 0.5% | |
LOAD REGULATION | ±1.0% | ± 0.5% | ± 0.5% | |
SETUP, RISE TIME | 200ms 100ms | |||
HOLD UP TIME (Typ.) | 30ms | |||
INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 370VDC | ||
FREQUENCY RANGE | 47~63Hz | |||
EFFICIENCY(Typ.) | 65% | 68% | 72% | |
AC CURRENT (Typ.) | 0.6A/115VAC 0.35A/230VAC | |||
INRUSH CURRENT (Typ.) | COLD START 13A/115VAC 25A/230VAC | |||
LEAKAGE CURRENT | <0.75mA/ 240VAC | |||
PROTECTION | OVERLOAD | 105 ~ 150% rated output power | ||
Protection type :Hiccup mode, recovers automatically after fault condition is removed. | ||||
ENVIRONMENT | WORKING TEMP. | -10 ~ +60°C (Refer to "Derating Curve") | ||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||
STORAGE TEMP., HUMIDITY | -20 ~ +85°C, 10 ~ 95% RH | |||
TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 50°C) | |||
VIBRATION | 10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes | |||
SAFETY & EMC (Note 4) | SAFETYSTANDARDS | UL1012, TUV EN60950-1 approved | ||
WITHSTAND VOLTAGE | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH | |||
EMC EMISSION | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 | |||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5, EN55024, light industry level, criteria A | |||
OTHERS | MTBF | 522.1K hrs min. MIL-HDBK-217F (25) °C | ||
DIMENSION | 85*58*38mm (L*W*H) | |||
PACKING | 0.19Kg; 100pcs/26Kg/0.9CUFT | |||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. | |||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor. | ||||
3. Tolerance : includes set up tolerance, line regulation and load regulation. |