Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 2 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ORDER NO. | S-800-12 | S-800-15 | S-800-24 | S-800-48 | |
OUTPUT | SAFETY MODEL NO. | 800-12 | 800-15 | 800-24 | 800-48 |
DC VOLTAGE | 12V | 15V | 24V | 48V | |
RATED CURRENT | 66A | 54A | 33A | 16.6A | |
CURRENT RANGE | 0 ~ 66A | 0 ~ 54A | 0 ~ 33A | 0 ~ 16.6A | |
RATED POWER | 800W | 800W | 800W | 800W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 240mVp-p | 480mVp-p | |
VOLTAGE ADJ. RANGE | ±5.0% typical adjustment by potentiometer 20~100% adjustment by 1 ~5VDC external control | ||||
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE, HOLD TIME | 800ms, 50ms, 16ms at full load | ||||
INPUT | VOLTAGE RANGE | 90~130VAC / 180 ~ 260VAC selected by switch, 260~370VDC | |||
FREQUENCY RANGE | 47~63Hz | ||||
EFFICIENCY (Typ.) | 80% | 81% | 85% | 87% | |
AC CURRENT | 13A/ 115VAC 8.0A/230VAC | ||||
INRUSH CURRENT (max.) | 60A/230VAC | ||||
LEAKAGE CURRENT (max.) | 3.5mA/ 240VAC | ||||
PROTECTION | OVER LOAD | 110~135% rated output power | |||
Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover | |||||
OVER VOLTAGE | 110~135% follow to output set up point | ||||
Protection type : Shut down o/p voltage, re-power on to recover | |||||
OVER TEMPERATURE | >100°C / measure by heat sink, near transformer | ||||
Protection type : Shut down o/p voltage, re-power on to recover | |||||
ENVIRONMENT | WORKING TEMP. | -10~+65°C (Refer to output load derating curve) | |||
WORKING TEMP., HUMIDITY | 20%~90% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -20~+85°C 10~95% RH | ||||
TEMP. COEFFICIENT | ±0.04% /°C (0~50°C) | ||||
VIBRATION | 10~200Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes | ||||
SAFETY & | SAFETY STANDARDS | Design refer to UL1950, CSA22.2, IEC60950 | |||
EMC (Note. 4) | |||||
WITHSTAND VOLTAGE | I/P-O/P, I/P-FG:1500VAC | ||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, >100M Ohms / 500VDC | ||||
EMI CONDUCTION & RADIATION | Design refer to FCC part 15 class A | ||||
OTHERS | MTBF | 120khrs min. MIL-HDBK-217F (25°C) | |||
DIMENSION | 291*132*68mm (L*W*H) | ||||
PACKING | 2.6kg; 8pcs/ 20.8kg /CARTON | ||||
SPECIAL FUNCTION | DC voltage adj., Remote sensing, remote control, parallel operation (refer to terminal instruction manual) | ||||
NOTE | 1.All parameters are specified at 230VAC input, rated load, 25°C 70% RH. Ambient. | ||||
2.Tolerence:includes set up tolerance, line regulation, load regulation. | |||||
3.Ripple& noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 uf & 47uf capacitor. | |||||
4.The power supply is considered a component which will be installed into a final equipment. | |||||
The final equipment must be re-confirmed that it still meets EMC directives. |