MODEL | M DR-60-5 | M DR-60-12 | M DR-60-24 | M DR-60-48 | |
DC VOLTAGE | 5V | 12V | 24V | 48V | |
RATED CURRENT | 10A | 5A | 2.5A | 1.25A | |
CURRENT RANGE | 0 ~ 10A | 0 ~5A | 0 -2.5A | 0-1.25A | |
RATED POWER | 50W | 60W | 60W | 60W | |
RIPPLE & NOISE (max.) Nota.2 | 80mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | |
OUTPUT | VOLTAGE ADJ. RANGE | 5 -6V | 12-15V | 24 - 30V | 48 ~ 56V |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LOAD REGULATION | ±1.5% | ±1.0% | ±1.0% | ±1.0% | |
SETUP, RISE TIME Note.5 | 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load | ||||
HOLD UP TIME (Typ.) | 50ms/230VAC 20ms/115VAC at full load | ||||
VOLTAGE RANGE | 85 - 264VAC 120-370VDC | ||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
INPUT | EFFICIENCY (Typ.) | 78% | 86% | 88% | 87% |
AC CURRENT (Typ.) | 1.8A/115VAC 1A/230VAC | ||||
INRUSH CURRENT (Typ.) | COLD START 30A/115VAC,60A/230VAC | ||||
LEAKAGE CURRENT | <1mA/240VAC | ||||
OVERLOAD | 105 - 150% rated output power | ||||
PROTECTION | Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||||
OVERVOLTAGE | 6.25-7.25V | 15.6 - 18V | 31.2-36V | 57.6 - 64.8V | |
Protection type: Shut down o/p voltage, re-power on to recover | |||||
FUNCTION | DC OK SIGNAL | Relay contact rating (max.): 30V/1A resistive | |||
WORKING TEMP. | -20 - +70°C (Refer to "Derating Curve") | ||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||
ENVIRONMENT | STORAGE TEMP., HUMIDITY | -40 ~ +85°C, 10 ~ 95% RH | |||
TEMP. COEFFICIENT | ±0.03%/°C (0 - 50°C) | ||||
VIBRATION | Component: 10 - 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 | ||||
SAFETY STANDARDS | UL508, UL60950-1, TUV EN60950-1 approved | ||||
SAFETY & | WITHSTAND VOLTAGE | l/P-0/P:3KVAC l/P-FG:2KVAC 0/P-FG:0.5KVAC | |||
EMC | ISOLATION RESISTANCE | l/P-O/P, l/P-FG, 0/P-FG:>100M Ohms/500VDC/25°C/70% RH | |||
(Note 4) | EMC EMISSION | Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3 | |||
EMC IMMUNITY | Compliance to EN6100(M-2,3,4,5,6,8,11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A | ||||
MTBF | 299.2K hrs min. MIL-HDBK-217F (25°C) | ||||
OTHERS | DIMENSION | 40*90*100mm (W*H*D) | |||
PACKING | 0.33Kg; 42pcs/14.8Kg/0.82CUFT | ||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. | ||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor. | |||||
3. Tolerance : includes set up tolerance, line regulation and load regulation. | |||||
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies. | |||||
5. 5.Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. | |||||